Effective Strategies for Managing a Legionella Positive

Effective Strategies for Managing a Legionella Positive

Managing a Legionella positive quickly and correctly is essential to protect health and stay compliant. Water systems in commercial environments must be tested regularly to ensure they are free from harmful bacteria like Legionella. When a positive test result is received, immediate and effective action is crucial to prevent potential health risks. Here’s how to effectively manage Legionella positives and safeguard your water systems.

What is a Legionella Positive?

A Legionella positive occurs when the bacteria Legionella is detected in a water system during routine testing. When Legionella is detected, your water hygiene provider will alert you with a Legionella-positive result. A water sample is tested for the bacteria, and if it is detected in your water system, the testing lab will send across a Legionella-positive result.

At this point, immediate action should be taken. This includes reviewing temperature control measures, biocide levels, and ensuring the cleanliness of your water system. Regular testing of water systems is crucial for ensuring safe water quality and preventing outbreaks.

In the UK, every water system used in a business environment should be risk assessed to determine where the Legionella risks lie. A risk assessment of your water system will assist in mitigating risk and detecting where there may be a potential risk of Legionella. Preventative measures are usually documented in risk assessments and addressed by the responsible person.

Deadleg Before - Effective Strategies For Managing A Legionella Positive
Managing A Legionella Positive, Deadlegs Need To Be Removed

 

A disused piece of pipework (dead leg) can be removed to eradicate the risk it poses. Alternatively, a rarely used yet still operational shower head can simply be flushed through regularly to reduce risk.At Legionella & Fire Safe Services, we deliver industry-leading compliance and remediation services to combat Legionnaires’ disease.

Need a Legionella test for your system? Get in touch with us today to schedule a comprehensive water test and request a free quote.

Managing a Legionella Positive

If you receive a Legionella positive result, it’s essential to act quickly. Here are the best strategies to manage the situation effectively.

Flushing the System

Undertaking a safe Legionella flushing regime and maintaining good water hygiene records will ensure the bacteria does not proliferate. Flush infrequently used outlets daily to reduce the risk of Legionella, and perform intensive cleaning and maintenance where required. Flushing the water system is one of the most effective ways to reduce Legionella growth. Keep shower heads and taps free of mould, algae, and limescale.

Managing A Legionella Positive
Unclean Water Tank

Periodically clean tanks with a chlorine solution and drain them to remove sediment and scale.

To prevent water stagnation, shorten pipe lengths and remove unused pipework.

Quick tip: After periods of non-use, such as holidays, run showers and taps for at least 5 minutes to clear out stagnant water and prevent bacteria growth.

Temperature Control and Disinfection

Thorough disinfection and flushing are essential steps in managing a Legionella positive. Legionella can be disinfected using both thermal and chemical methods. Heating water to 70°C for at least three minutes, and up to two hours, can kill bacteria effectively. Regular dosing with biocides will keep your water systems clean and safe. Add a biocide to the water system at a controlled dose, then open taps and outlets to allow the disinfectant to reach every part of the system.

Quick tip: Ensure your system receives consistent disinfection treatment to minimise the risk of future outbreaks.

Filtration for Added Protection

Adding point-of-use filters to outlets like showers, sprinklers, or hot tubs can reduce the risk of Legionella by preventing bacteria from spreading through aerosolised water droplets. The aim is to keep water in use and turning over. Remove the affected outlet(s) from use and undertake a similar or more extensive re-sampling programme in the short term. We suggest prohibiting the use of, or fitting point-of-use filters with 0.2µm membranes to, all aerosol outlets.

Re-sampling and Ongoing Testing

Once a Legionella positive test occurs, re-sampling helps ensure that your water management measures are working. Consistent testing will also identify any recurrent issues within the system. By tracking results, you can adjust your control measures proactively. Review previous and subsequent results for further failures, and take further pre- and post-flush samples from a representative number of outlets on the same system, or in the same area, to identify the source of the contamination. Check whether the positive results are coming from the same locations, as this might indicate a persistent problem in specific areas of the water system.

Reviewing and Strengthening Control Measures

Implement a water management programme to control the growth and spread of Legionella. Conduct a risk assessment for all systems that use or store water, and keep a record of all precautionary measures and control treatments. The responsible person must ensure that staff are appropriately trained to manage and control the risks posed by Legionella. If the control levels in the water treatment programme (temperature or chemical concentrations) are not met, a thorough review and appropriate action are necessary.

Conduct frequent Legionella testing, initially weekly, to ensure the system is under control. Once control is established, review the testing frequency. Review the effectiveness of control measures implemented in the past, including temperature control, biocide use, and regular flushing of the system.

Do You Need a Complete Water Management Programme?

At Legionella & Fire Safe Services, we provide comprehensive Legionella control services that fit your needs. Don’t wait until it’s too late. Contact us today to keep your water systems safe and compliant. Whether you need routine testing, emergency response, or ongoing maintenance, our team is ready to help.

Info@legionellaandfiresafe.co.uk

0800 080 3045

MOST RECENT

Water temperature testing to help manage winter Legionella risks

Legionella Doesn’t Take a Winter Break: Protecting Your Water Systems

Winter Legionella risks are often overlooked when colder weather arrives. Heating, draughts and burst pipes tend to take priority, but changes in building occupancy and...
£166k Fire Safety Fine: Lessons for Landlords | LFS

£166k Fire Safety Fine: Lessons for Landlords | LFS

£166k Fire Safety Fine: Lessons for Landlords | LFS 14 Oct 2026 · A property management company has been ordered to pay more than £166,000...
Electric Fireplace Legionella Outbreak:

Electric Fireplace Legionella Outbreak: 21 Cases Explained

Electric Fireplace Legionella Outbreak: 21 Cases Explained The fireplace that caused a Legionnaires’ outbreak: why decorative mist devices belong in your risk assessment 13 Oct...