Legionella Doesn’t Take a Winter Break: Protecting Your Water Systems

Winter Legionella risks are often overlooked when colder weather arrives. Heating, draughts and burst pipes tend to take priority, but changes in building occupancy and water usage can create conditions where Legionella bacteria become a concern.

Why Quieter Buildings Increase Winter Legionella Risks

Legionella bacteria can multiply in water systems where temperatures are between approximately 20°C and 45°C, particularly when water is allowed to stagnate.

During winter, reduced occupancy can create conditions where water remains unused for extended periods.

Common examples include:

  • Schools and educational buildings closed during holidays.
  • Offices operating at reduced capacity.
  • Vacant properties managed by housing associations.
  • Guest accommodation with lower occupancy.
  • Little used washrooms, kitchens and shower facilities.

When water remains stationary, disinfectant residuals may decline and conditions can become more favourable for bacterial growth.

Redundant pipework and dead legs can present additional risks, particularly where water is unable to circulate effectively.

These are precisely the areas that should be considered within a suitable Legionella risk assessment.

Water Temperature Control During Winter

Temperature control remains one of the most important measures for managing Legionella risks.

As a general guide for hot and cold water systems:

  • Hot water should be stored at 60°C or above.
  • Hot water should reach at least 50°C within one minute at relevant outlets, with higher requirements in certain healthcare settings.
  • Cold water should be maintained below 20°C.

Winter presents some less obvious challenges.

Cold water pipework passing through heated areas may become warmer than intended, while hot water in lengthy pipe runs or infrequently used outlets may cool into the temperature range that encourages Legionella growth.

Regular temperature monitoring helps identify whether a system is operating within its intended control limits.

Checks should be carried out in accordance with the building’s water hygiene management arrangements, with results recorded and any failures investigated.

Why Regular Flushing Matters

One of the simplest ways to reduce stagnation is to ensure that infrequently used outlets are flushed regularly.

The Health and Safety Executive recommends flushing outlets that are not frequently used at least weekly, as part of an appropriate control programme.

This helps replace stagnant water with fresh water from the distribution system.

Flushing should be carried out in a controlled manner, minimising the release of aerosols and following the site’s written procedures.

Duty holders should also:

  • Identify taps, showers and other outlets receiving little use.
  • Maintain an appropriate flushing schedule.
  • Record completed flushing activities.
  • Investigate outlets that cannot achieve suitable temperatures.
  • Consider removing redundant pipework and outlets where appropriate.

A consistent programme is particularly important in buildings with changing occupancy or prolonged periods of closure.

Does Your Legionella Risk Assessment Still Reflect Your Building?

A Legionella risk assessment should reflect how a building and its water systems are actually being used.

If occupancy has changed, parts of the building have closed, or water systems have been altered, existing control measures may no longer be suitable.

Under the HSE’s Approved Code of Practice L8 and supporting HSG274 guidance, duty holders must assess and adequately control the risks associated with Legionella.

Risk assessments should be reviewed regularly and whenever there is reason to believe they are no longer valid.

Changes in building use, water system operation or monitoring results can all justify a review.

Protecting Your Water Systems This Winter

Effective Legionella management doesn’t stop when temperatures drop.

Regular flushing, temperature monitoring, appropriate maintenance and a suitable risk assessment all play an important role in protecting building occupants.

At Legionella & Fire Safe Services, our experienced water hygiene team supports housing associations, local authorities, facilities managers and commercial organisations across the UK.

We provide professional Legionella risk assessments, compliance support and ongoing water hygiene monitoring in accordance with HSE guidance, including ACoP L8 and HSG274.

As members of the Legionella Control Association, we understand the importance of practical, documented control measures that reflect the needs of each building.

Not confident your water systems are ready for winter?

Speak to the LFS team about reviewing your Legionella risk assessment and ensuring your control measures remain appropriate.

Call 0800 080 3045

Protecting People and Property. It starts with getting the basics right.

MOST RECENT

Fire door compliance inspection: a closed fire door with a Fire Door Keep Shut sign in a UK corridor

Fire Door Compliance: 4 Duties You Cannot Ignore

Fire door compliance is one of the clearest duties facing anyone responsible for premises, yet fire doors rarely get a second thought until something goes...
Fire extinguisher beside a fire safety checklist

Fire Safety Enforcement Is Rising: Why Your Fire Risk Assessment Matters More Than Ever

Fire safety enforcement in England is rising, with prohibition notices up 27%. Find out why a current fire risk assessment is your best protection.
Fire door in a shared hallway of a house in multiple occupation.

HMO Fire Door Failings: Lessons From the £15,000 Barrow Fine

No Fire Doors, No Alarm, No Licence: What the £15,000 Barrow HMO Fine Means for Landlords Missing HMO fire doors were among several safety failings...