Fire safety failings can lead to enforcement before a fire happens

Fire safety failings can lead to enforcement before a fire happens

 

Fire safety failings do not have to result in a fire before enforcement action follows.

That is the clear message from a recent prosecution brought by Lancashire Fire and Rescue Service following serious fire safety failings at two occupied residential buildings.

The case is a timely reminder for landlords, housing providers, facilities managers and anyone responsible for building safety. Fire precautions must not simply exist on paper. They must be suitable, properly maintained and capable of protecting people if a fire occurs.

What happened in the Lancashire case?

On 2 October 2026, Lancashire Fire and Rescue Service reported that a landlord and property company had been prosecuted following inspections at Belgrave Chapel in Darwen and Victoria Hall in Bacup.

Both buildings were occupied when fire safety officers identified serious deficiencies. These included:

  • Damaged fire doors
  • Missing fire resisting glazing
  • Obstructed escape routes
  • Inadequate fire detection measures
  • Fire alarm systems that were switched off or had no power
  • Inadequate fire safety management arrangements
  • Failure to comply with enforcement action

The landlord pleaded guilty to 11 offences and the company pleaded guilty to nine offences under the Regulatory Reform (Fire Safety) Order 2005.

The company was fined £200,000. The director received a 12 month prison sentence, suspended for 12 months, together with a separate fine. The company and director were also ordered to pay substantial costs.

The full details are available from Lancashire Fire and Rescue Service.

Enforcement does not depend on a fire occurring

What stands out about this case is that the enforcement action followed inspections of the buildings. It was not necessary for a fire, injury or fatality to occur before action was taken.

Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person must ensure that appropriate fire precautions are in place. This includes completing and regularly reviewing a suitable and sufficient fire risk assessment.

Where serious risks are identified and not properly managed, enforcing authorities can issue formal notices, restrict the use of a building and pursue prosecution.

A fire risk assessment is therefore not simply a document to produce when requested. It should accurately reflect the building, the people using it and the precautions currently in place.

Why damaged fire doors are a serious concern

Fire doors form an important part of a building’s passive fire protection.

When correctly specified, installed and maintained, they help to restrict the movement of fire and smoke, protect escape routes and support the building’s compartmentation strategy.

Their performance depends on the complete doorset. This includes the door leaf, frame, hinges, closer, seals, glazing, ironmongery and the gaps around the door.

A door may appear acceptable during a quick visual check while still having defects that could affect its performance. Damage, unsuitable components, excessive gaps, poorly fitted seals or a closer that does not shut the door correctly must not be overlooked.

Government guidance confirms that fire doors should be maintained in good working order and that replacement work should be completed by a competent person where an existing door is inadequate.

Fire risk assessments must lead to action

Completing a fire risk assessment is only the beginning.

Any defects identified should be recorded, prioritised and followed through to completion. If significant findings remain unresolved, the risk to occupants remains.

Organisations responsible for multiple buildings need a clear process covering:

  • Ownership of every corrective action
  • Timescales based on the level of risk
  • Competent contractors for specialist work
  • Evidence of completed repairs and installations
  • Updated records for each building
  • Regular review of outstanding actions
  • Further assessment following significant changes

This is particularly important after refurbishment, maintenance or the installation of new building services. New pipes, cables and ducts can pass through fire resisting walls and floors, leaving openings that compromise compartmentation if they are not correctly fire stopped.

Do your fire safety arrangements reflect the building today?

Buildings change over time.

Layouts are altered, rooms are used differently, occupancy levels change and new services are installed. Fire doors are also exposed to daily use, accidental damage and unauthorised alterations.

Your fire risk assessment and fire safety arrangements should reflect the building as it is now, not how it was several years ago.

Responsible persons should be able to demonstrate what has been assessed, what defects were identified, what action was taken and how ongoing compliance is being managed.

How LFS can support your organisation

Legionella & Fire Safe Services supports housing providers, local authorities, facilities management companies, landlords and commercial organisations with fire safety across individual buildings and wider property portfolios.

Our services include:

  • Fire risk assessments
  • Fire door surveys
  • Digital reporting
  • Fire door installation and maintenance
  • Compartmentation assessments
  • Fire stopping surveys and corrective works
  • Passive fire protection support

As a BM TRADA approved fire door installer, LFS can help clients manage fire door requirements from the initial survey through to installation, maintenance and completion of identified corrective work.

If you are unsure whether your current fire safety arrangements accurately reflect your buildings, speak to our team.

Legionella & Fire Safe Services

0800 080 3045
info@legionellaandfiresafe.co.uk
legionellaandfiresafe.co.uk

MOST RECENT

Fire door compliance inspection: a closed fire door with a Fire Door Keep Shut sign in a UK corridor

Fire Door Compliance: 4 Duties You Cannot Ignore

Fire door compliance is one of the clearest duties facing anyone responsible for premises, yet fire doors rarely get a second thought until something goes...
Fire extinguisher beside a fire safety checklist

Fire Safety Enforcement Is Rising: Why Your Fire Risk Assessment Matters More Than Ever

Fire safety enforcement in England is rising, with prohibition notices up 27%. Find out why a current fire risk assessment is your best protection.
Fire door in a shared hallway of a house in multiple occupation.

HMO Fire Door Failings: Lessons From the £15,000 Barrow Fine

No Fire Doors, No Alarm, No Licence: What the £15,000 Barrow HMO Fine Means for Landlords Missing HMO fire doors were among several safety failings...